1. 程式人生 > >Juniper QFX5100交換機et接口input error及CRC/Align errors

Juniper QFX5100交換機et接口input error及CRC/Align errors

Juniper QFX5100 Switch 40G Network

故障現象:Juniper QFX5100-24Q通過監控發現et-0/0/2上出現Error包。


通過命令:show interfaces et-0/0/2 extensive,顯示input error以及CRC錯誤。


狀態顯示:


Physical interface: et-0/0/2, Enabled, Physical link is Up

Interface index: 942, SNMP ifIndex: 516, Generation: 676

Link-level type: Ethernet, MTU: 1514, Speed: 40Gbps, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled, Media type: Fiber

Device flags : Present Running

Interface flags: SNMP-Traps Internal: 0x4000

Link flags : None

Input errors:

Errors: 771731, Drops: 0, Framing errors: 771415, Runts: 0, Policed discards: 0, L3 incompletes: 0, L2 channel errors: 0, L2 mismatch timeouts: 0, FIFO errors: 0, Resource errors: 0

Output errors:

Carrier transitions: 3, Errors: 0, Drops: 0, Collisions: 0, Aged packets: 0, FIFO errors: 0, HS link CRC errors: 0, MTU errors: 0, Resource errors: 0

…………………………

MAC statistics: Receive Transmit

Total octets 1216533781969 1073277356863

Total packets 1669078594 1462519491

Unicast packets 1633851744 1398747806

Broadcast packets 361455 27733729

Multicast packets 34865395 36037956

CRC/Align errors 771415 0

FIFO errors 0 0


初步排查,影響的原因有可能是以下幾點:

1. 接口模塊

2. 光線或網線

3. 兩邊接口是否全雙工


解決辦法:

經換模塊,CRC顯示正常,input error恢復正常。 開Case,對模塊進行RMA處理。




Juniper QFX5100交換機et接口input error及CRC/Align errors